import serial
|
|
import time
|
|
import numpy as np
|
|
|
|
timedelta = 0.02
|
|
|
|
class AG_304_FS:
|
|
|
|
def __init__(self,adress):
|
|
#establish connection to device
|
|
try:
|
|
self.inst = serial.Serial(adress, 9600, timeout=1) # Replace with your COM port and baudrate
|
|
print(f'connected to {adress}')
|
|
except:
|
|
print(f'could not connect to {adress}')
|
|
return
|
|
time.sleep(1)
|
|
|
|
def __del__(self):
|
|
self.inst.close()
|
|
print('Disconnected')
|
|
|
|
def read_pressure(self):
|
|
'''read the pressure from the controller (Window 224, see manual)'''
|
|
hex_string = "028032323430033837" # pressure
|
|
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
val_b = data_b[6:13]
|
|
try:
|
|
val = float(val_b)
|
|
except ValueError:
|
|
val = 0
|
|
return(val)
|
|
|
|
def read_temp(self):
|
|
'''read the pump temperature (Window 204)'''
|
|
hex_string = "028032303430033835" # temperature
|
|
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
val_b = data_b[6:12] #get rid of additional bytes
|
|
try:
|
|
val = float(val_b)
|
|
except ValueError:
|
|
val = 0
|
|
return(val)
|
|
|
|
def read_status(self):
|
|
'''read pump status (window 205)'''
|
|
hex_string = "028032303530033834" # status
|
|
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
val_b = data_b[6:12] #get rid of additional bytes
|
|
status = ['Stop', 'Waiting intlk', ' Starting', 'Autotuning', 'Braking', 'Normal', 'Fail']
|
|
try:
|
|
val = int(val_b)
|
|
except ValueError:
|
|
val = 6
|
|
return(status[val])
|
|
|
|
def read_freq(self):
|
|
'''read pump frequency [Hz] (window 203)'''
|
|
hex_string = "028032303330033832" # temperature
|
|
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
val_b = data_b[6:12] #get rid of additional bytes
|
|
try:
|
|
val = int(val_b)
|
|
except ValueError:
|
|
val = 0
|
|
return(val)
|
|
|
|
def read_fan_status(self):
|
|
'''reads the status of the fan (window 144)'''
|
|
hex_string = "028031343430033832"
|
|
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
val_b = data_b[5:7] #get rid of additional bytes (Response is different here compared to others)
|
|
val = int(val_b)
|
|
return(val)
|
|
|
|
def set_fan_status(self,on):
|
|
'''sets the status of the fan (window 144)'''
|
|
if on == True or on == 'On' or on == 'ON' or on == 'on' or on == 1:
|
|
hex_string = "02803134333132034236" # sets external fan activation to on
|
|
# hex_string = "02803134343130034233"
|
|
else:
|
|
hex_string = "02803134333131034235" # sets external fan activation to off
|
|
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
print(data_b)
|
|
val_b = data_b[5:7] #get rid of additional bytes (Response is different here compared to others)
|
|
val = int(val_b)
|
|
return(val)
|
|
|
|
def start_pump(self):
|
|
'''start pump (Window 000)'''
|
|
hex_string = "02803030303131034233"
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
# if data_b[2:3] == b'\x06':
|
|
# print('Starting Pump')
|
|
# else:
|
|
# print('Pump cannot be started.')
|
|
|
|
def stop_pump(self):
|
|
'''stop pump (Window ...)'''
|
|
hex_string = "02803030303130034232"
|
|
# Convert the hex string to bytes
|
|
bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# Send the bytes to the COM port
|
|
self.inst.write(bytes_to_send)
|
|
# Read response
|
|
data_b = self.inst.read(100) # read up to hundred bytes or timeout is reached
|
|
# if data_b == data_b[2:3] == b'\x06':
|
|
# print('Stop Pump')
|
|
# else:
|
|
# print('Pump cannot be stopped.')
|
|
|
|
|
|
# test area
|
|
# adress = 'COM2'
|
|
# ag = AG_304_FS(adress)
|
|
# print(ag.read_pressure())
|
|
# ag.__del__()
|
|
|
|
##Open the COM port
|
|
# ser = serial.Serial('COM2', 9600, timeout=1) # Replace with your COM port and baudrate
|
|
|
|
# # Define the hex string
|
|
# hex_string = "028032303530033834" # pump status
|
|
# hex_string = "028032323430033837" # pressure
|
|
|
|
# # Convert the hex string to bytes
|
|
# bytes_to_send = bytes.fromhex(hex_string)
|
|
|
|
# # Send the bytes to the COM port
|
|
# ser.write(bytes_to_send)
|
|
# # Read response
|
|
# s = ser.read(100) # read up to ten bytes (timeout)
|
|
# print(s)
|
|
|
|